HTM-Water Pipes De-Icing Self regulating Heating Cables

Trade Information

  • Brand Name:Jiahong
  • Place of Origin:Anhui,China
  • Min. Order Quantity:500m/model
  • Shipping Port:Any port in China
  • Lead Time:10-25 days after received payment
  • Payment Terms:100% TT in advance or negotiable
  • Certificates:ETL , EAC , CE

Product description

Download PDF

Features

.Energy efficient automatically varies its power output in response to pipe temperature changes.

.Easy to install, can be cut to any length (up to max circuit length) required on site with no wasted cable.

.Lower installed cost than steam tracing, less maintenance expense and less downtime.

.No overheat or burnout even when wrapped over itself (overlapped).

.Suitable for use in non-hazardous, hazardous and corrosive environments.

.Jiahong power connection, splice, tee and end seal kit will reduce installation time.


Description

HTM increases or decreases the heat output in a self- regulating way depending on the change of the ambient temperature, so a thermostat may not be necessary in some applications and it will never overheat or burnout even when wrapped over itself (overlapped). With optional outer-jacket, the heating cable is resistant to watery and inorganic chemicals and protects against abrasion and impact damage. HTM is suitable for use in explosion- hazardous areas up to a maximally admissible work-piece temperature of 150℉(65℃). Jiahong provides termination,power connection, splice, tee and end seal kit will reduce installation time and require no special skills or tools.


Application

HTM is self-regulating parallel heating cable (heating tape) which can provide safe, reliable heat tracing for freeze protection or temperature maintenance of pipes, valves,flanges, keeping water flowing at -40℉(-40℃). It is suitable for use on small diameter plastic or metal pipes.



Heating cable construction


Options

HTM…C    Tinned copper braid provides additional mechanical protection and a positive ground path.

HTM…CR  Flame retardant thermoplastic outer jacket protects against certain inorganic chemical solutions, it also protects against abrasion and impact damage.

HTM…CT  High-Temperature Fluoropolymer outer jacket is used for exposure to organic or corrosive solutions or vapors may be present.


Technical data

Service voltage          
 110-120V,   208-277V

Maximum maintain or continuous

exposure temperature(power on)

 +65℃(150℉)

Maximum intermittent exposure Temperature, 1000 hours(power on or off)

 +85℃(185℉)
Minimum installation temperature
 -40℃(-40℉)
Protective braid resistance
 ﹤18.2Ω/km
Bus wire gauge
 20AWG
Approvals
 ETL / EAC / CE


Dimension and weight

Type

Dimension

Weight (kg/100m)

HTM…C

6.7×4.1mm

5.0

HTM…CR

8.3×5.7mm

6.5

HTM…CT

7.7×5.1mm

6.8

Minimum bend radius@68℉(20℃): 12 mm


Product ordering information


Power output curves

Nominal power output at 240V when HTM installed on insulated metal pipes.