Electrical freeze protection for long pipe- lines in both nonhazardous and hazardous locations

Description

The LHTR self-regulating heating cables provide freeze protection and low-temperature maintenance for long line applications. The LHTR heating cables maintain process temperatures up to 150°F (65°C) and can withstand intermittent exposure to temperatures up to 185°F (85°C).The cables are configured for use in non- hazardous and hazardous locations, including areas where corrosives may be present.The LHTR heating cables provide long circuit length capability. They can be used for continuous circuit lengths up to 1125 feet (342 m) powered from a single source.

LHTR cables are especially well suited for tracing long pipelines containing temperature sensitive fluids or where high reliability is required.



Application

Area classification

Non-hazardous and  hazardous locations

Traced surface type

Metal and plastics

Chemical resistance

Organic and aqueous inorganic chemicals and corrosives

Supply Voltage

208–277 Vac

Maximum maintain or continuous exposure temperature (power on)

150°F (65°C)

Maximum intermittent exposure temperature, 1000 hours (power on or off)

185°F (85°C)

Minimum installation temperature

–40°F (–40°C)

Temperature ID Number (T-Rating)

T6, 185°F (85°C)


Nominal Power Output Rating on Metal Pipes

Power output

Circuit length

208V

0.93

0.88

277V

1.08

1.11


Maximum Circuit Lengths Based on Circuit Breaker Sizes

Ambient temperature at start-up

Maximum circuit length (in feet)per circuit breaker

240V

15A

20A

30A

40A

50A

60A

70A

7LHTR-CT

40℉ (4℃)

305

410

630

875

1125

1125

1125

20℉ (-7℃)

250

335

510

700

915

1125

1125

0℉  (-18℃)

210

280

425

585

755

955

1125

-20℉ (-29℃)

180

240

365

500

645

810

995

-40℉ (-40℃)

160

210

320

440

560

700

855


Ambient temperature at start-up

Maximum circuit length (in feet)per circuit breaker

240V

40A

50A

70A

40A

50A

70A

3.5LHTR-CT

32℉ (0℃)

1610

1720

630

875

1125

1125

0℉  (-18℃)

1180

1600

510

700

915

1125

-20℉ (-29℃)

1010

1340

425

585

755

955

-40℉ (-40℃)

880

1160

365

500

645

810

-60℉ (-51℃)

780

1030

320

440

560

700