About Protrace
Email Us
driveway heating cable
driveway heating cable1
pipe-frost-protection-cable
driveway heating cable
driveway heating cable1
pipe-frost-protection-cable

Pipe Freeze Protection Cable

    • Prevents pipes from freezing, keeping water flowing at -40oC;

    • The maximum maintenance temperature is 85oF(30oC);

    • Pre-assembled, ready to install;

    • Emits zero electromagnetic fields;

    • Built-in energy saving thermostat;

    • Approved by CE, ATEX, IECEX, EAC, UL, ETL, and CSA;

    • 3 Years Warranty;


Request A Quote

Why Choose Jiahong's Pipe Freeze Protection Cable?

<p>No.1 Heating Cable Exporter in Asia-Pacific</p>

No.1 Heating Cable Exporter in Asia-Pacific

<p>Over 25 Years of Manufacturing Experience</p>

Over 25 Years of Manufacturing Experience

<p>The Third Party Audit and ISO9001 Quality Approved</p>

The Third Party Audit and ISO9001 Quality Approved

<p>Independent R&D Teams</p>

Independent R&D Teams

<p>Complete Production Lines Support and Fast Delivery</p>

Complete Production Lines Support and Fast Delivery

<p>Supports One Stop Sourcing</p>

Supports One Stop Sourcing

  • Features
  • Specification
  • JHSD Heat Resistant Cable

    Jiahong Heat Resistant Cable is a kind of twin-conductor constant wattage heating cable. It is a well pre-assembled heating cable. It is designed for the sole use of preventing plastic or metal water pipes from freezing and keep the liquid flowing down to -40oC. It is popular in both America and Europe. In Europe, the regular types are 12w/m. and 15w/m. And the type of 7w/ft. is popular in America market.

    Jiahong electric ice melting cable heats up through the inner heating conductor and it cannot be cut at any circumstances. Different parts cannot overlap each other as well. The cable may work under the rated voltages of 120Vac or 240Vac, or 230Vac. The maximum ambient temperature is 85°F (30oC) and the minimum installation temperature is 15°F (-10oC).

    Jiahong Heat Resistant Cable consists of three different parts: the heating cable, cold lead, and an integrated thermostat. The cold lead shall connect to the plug and the heating cable provides the heat. The cold lead is a regular electric wire with plug. Both European standard plugs and North American standard plugs are available. The integrated thermostat is often mounted at the end of the complete cable. It works normally when ambient temperate ranges from 3oC to 10oC. It saves on energy consumption.

    Jiahong Heat Resistant Cable is simple and easy to install because it has a flat double-conductor structure design. However, different parts of the cable never overlap each other during the installation. Double-conductor can be seen as a complete wire because the two conductors are connected together at one end. Each Jiahong Heat Resistant Cable has a specific length. Most customers may choose some regular sizes from us according to their practical power demands. The length ranges from 2 to 25 meter are common in the European markets and 3 to 80ft are popular in the American markets.Every heating cable has already been approved by UL, ETL, and CSA in North America, and by CE and TUV in Europe.


  • Catalog Number

    Voltage

    V

    Cable

    Length/ft

    m

    Output

    W/ft

    WattsAmpsohms
    JHSD-21-112037210.2685.7
    JHSD-42-112067420.4342.9
    JHSD-63-112097630.5228.6
    JHSD-84-1120127840.7171.4
    JHSD-105-11201571050.9137.1
    JHSD-126-11201871261.1114.3
    JHSD-168-11202471681.485.7
    JHSD-210-11203072101.868.6
    JHSD-280-11204072802.351.4
    JHSD-420-11206074203.534.3
    JHSD-560-11208075604.725.7







    Catalog Number

    Voltage

    V

    Cable

    Length/ft

    m

    Output

    W/ft

    WattsAmpsohms
    JHSD-42-224067420.21371.4
    JHSD-63-224097630.3914.3
    JHSD-84-2240127840.4685.7
    JHSD-105-22401571050.5548.6
    JHSD-126-22401871260.6457.1
    JHSD-168-22402471680.7342.9
    JHSD-210-22403072100.9274.3
    JHSD-280-22404072801.2205.7
    JHSD-420-22406074201.8137.1
    JHSD-560-22408075602.4102.9


    Catalog Number

    Voltage

    V

    Cable

    Length/ft

    m

    Output

    W/m

    WattsAmpsohms
    JHSD-24-2230.02.012.024.00.12204.2
    JHSD-48-4230.04.06.048.00.21102.1
    JHSD-72-6230.06.012.072.00.3734.7
    JHSD-96-8230.08.012.096.00.4551.0
    JHSD-120-10230.010.012.0120.00.5440.8
    JHSD-180-15230.015.012.0180.00.8293.9
    JHSD-240-20230.020.012.0240.01.0220.4
    JHSD-300-25230.025.012.0300.01.3176.3


    Catalog Number

    Voltage

    V

    Cable

    Length/

    m

    Output

    W/m

    WattsAmpsohms
    JHSD-30-2230.02.015.030.00.11763.3
    JHSD-60-4230.04.015.060.00.3881.7
    JHSD-90-6230.06.015.090.00.4587.8
    JHSD-120-8230.08.015.0120.00.5440.8
    JHSD-150-10230.010.015.0150.00.7352.7
    JHSD-225-15230.015.015.0225.01.0235.1
    JHSD-300-20230.020.015.0300.01.3176.3
    JHSD-375-25230.025.015.0375.01.6141.1