WiFi Thermostat #ET-63

Request A Quote
  • Features
  • Specification

  • Function & Operation

    The product can switch two control modes, one is thermostat mode and the other is timer mode.


    Thermostat mode


    ON/OFF

    When frost protection is active, the thermostat will maintain the frost protection temp when it is OFF.


    TEMPORARY OVERRIDE TEMPERATURE

    The temporary override temp is only valid at the current event and it will not be saved.


    KEY-LOCK

    Lock all keys to prevent the settings from being changed.


    SET THE TIME

    If the thermostat is WiFi version, it will update time automatically after connecting to WiFi.


    HOLIDAY MODE

    In Holiday Mode, the thermostat will maintain the set temp until the holiday time ends.


    HOLD MODE

    In Hold Mode, The thermostat will hold the set temp until you cancel this mode.


    EDIT SETTING

    Edit Setting can set and change the parameters. If you don't choose Holiday Mode or Hold Mode. The thermostat runs according to the parameters of Edit.


    ADVANCED SETTING

    1. Room temp calibration: Calibrate the temp detected by room sensor.

    2. Floor temp calibration: Calibrate the temp detected by floor sensor.

    3. Anti-frozen function: This option allows you to bring warmth to your plant and pet with a lower temp.displays when you turn off the thermostat. In hydronic heating system, it will keep away from freezing.

    4. Sensor selection:

      00 Room sensor

      01 Floor sensor

      02 Room+Floor: Run by room sensor with floor temp limit.

      03 Room out

      04 Room out + Floor

    5. Floor temp limit: If you choose both sensors, floor temp limit must be set to protect floor.

    6. Temp unit:°C and °F can be selected.

    7. Output delay: This option helps you avoid inadvertent operation on heating.

    8. Temp deviation: The deviation is 1°C.The thermostat start to work when the actual temp is 1°C lower than set temp and stop to work when the actual temp is 1°C higher than set temp.

    9. Reverse output: This function works for the cooling system. When the temp is 1°C  higher than set temp, the thermostat will  disconnect the cooling system, otherwise it will connect the cooling system.

    10. Schedule: Select a weekly schedule for the Edit.

      There are 2 options:

      7: each day from Mon to Sun can be set individually.

      5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.

    11. Adaptive function: After several days of installation and use, adaptive function ensures that the required temp has already been reached when the next event begins.

    12. Reset: All parameters are restored to default values.



    Timer clock mode

    When used as a timer, only the symbols shown below are used.


    AUTOMATIC WEEKLY PROGRAM

    When the timer mode is entered, the weekly program is executed by default.

    The time clock offers three programming methods;

    Weekday/ Weekend (5+1+1):

    Allows you to program 4 on/off switching times for the weekdays and 4 on/off switching times for the weekend.

    7 Day Program Mode:

    Each day has 4 on/off switching times that can be programmed independently.

    24 Hour Mode:

    All days are programmed with the same on/off switching times.


    EDIT SETTING

    Edit Setting can set and change the parameters.


    HOLIDAY TIMING

    During holiday timing, the timer is turned off.


    ADVANCED SETTING

    These are normally set by technicians during initial installation.

  • Supply voltage:  85-265Vac 50/60Hz

    Standby power:  <1W

    Max load:  16A(electric heating)/3A(water heating)

    IP class: IP21

    Cable specification:   ≤2.5mm²